Escucha y lee

Descubre un mundo infinito de historias

  • Lee y escucha todo lo que quieras
  • Más de 900 000 títulos
  • Títulos exclusivos + Storytel Originals
  • 7 días de prueba gratis, luego $169 MXN al mes
  • Cancela cuando quieras
Copy of Device Banner Block 894x1036 3

Introduction to Power System Protection

Idioma
Inglés
Format
Categoría

No ficción

Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers

The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0–5 ampere range for convenience of measurement.

The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When |I'| exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open.

System-protection components have the following design criteria: • Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. • Selectivity: Avoid unnecessary, false trips. • Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. • Economy: Provide maximum protection at minimum cost. • Simplicity: Minimize protection equipment and circuitry.

Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection.

The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.

© 2022 Dr. Hidaia Mahmood Alassouli (eBook): 9783985103119

Fecha de lanzamiento

eBook: 12 de mayo de 2022

Tags

    Otros también disfrutaron...

    Explora nuevos mundos

    • Más de 900,000 títulos

    • Modo sin conexión

    • Kids Mode

    • Cancela en cualquier momento

    ¡Más popular!
    Oferta por tiempo limitado

    Ilimitado

    Nada mejor que un audiolibro para esta temporada.

    $169 /mes
    • 1 cuenta

    • Acceso ilimitado

    • Escucha y lee los títulos que quieras

    • Modo sin conexión + Kids Mode

    • Cancela en cualquier momento

    Pruébalo ahora

    Ilimitado Anual

    Escucha y lee sin límites a un mejor precio.

    $1190 /año
    7 días gratis
    Ahorra 40%
    • 1 cuenta

    • Acceso ilimitado

    • Escucha y lee los títulos que quieras

    • Modo sin conexión + Kids Mode

    • Cancela en cualquier momento

    Pruébalo ahora

    Familiar

    Perfecto para compartir historias con toda la familia.

    Desde $259 /mes
    7 días gratis
    • 4-6 cuentas

    • 100 horas/mes para cada cuenta

    • Acceso a todo el catálogo

    • Modo sin conexión + Kids Mode

    • Cancela en cualquier momento

    4 cuentas

    $259 /mes
    Pruébalo ahora