Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers

The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0–5 ampere range for convenience of measurement.

The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When |I'| exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open.

System-protection components have the following design criteria: • Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. • Selectivity: Avoid unnecessary, false trips. • Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. • Economy: Provide maximum protection at minimum cost. • Simplicity: Minimize protection equipment and circuitry.

Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection.

The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.

© 2022 Dr. Hidaia Mahmood Alassouli (E-bok): 9783985103119

Utgivelsesdato

E-bok: 12. mai 2022

Tagger

    Andre liker også ...

    Derfor vil du elske Storytel:

    • Over 700 000 bøker

    • Eksklusive nyheter hver uke

    • Lytt og les offline

    • Kids Mode (barnevennlig visning)

    • Avslutt når du vil

    Det mest populære valget

    Unlimited

    For deg som vil lytte og lese ubegrenset.

    219 kr /måned
    50 % i 2 måneder
    • 1 konto

    • Ubegrenset lytting

    • Lytt så mye du vil

    • Over 700 000 bøker

    • Nye eksklusive bøker hver uke

    • Avslutt når du vil

    50 % i 2 måneder
    Familiens førstevalg

    Family

    For deg som ønsker å dele historier med familien.

    Fra 289 kr/måned
    50 % i 2 måneder
    • 2-3 kontoer

    • Ubegrenset lytting

    • Lytt så mye du vil

    • Over 700 000 bøker

    • Nye eksklusive bøker hver uke

    • Avslutt når du vil

    2 kontoer

    289 kr /måned
    50 % i 2 måneder

    Basic

    For deg som lytter og leser av og til.

    149 kr /måned
    • 1 konto

    • 20 timer/måned

    • Lytt opp til 20 timer per måned

    • Over 700 000 bøker

    • Nye eksklusive bøker hver uke

    • Avslutt når du vil

    Prøv gratis

    Student

    Verifiser deg med din student-ID og få halv pris hele livet.

    74.50 kr /måned
    • 1 konto

    • 20 timer/måned

    • Lytt opp til 20 timer per måned

    • Studentpris med 50 % rabatt hele livet!

    • Over 700 000 bøker

    • Nye eksklusive bøker hver uke

    • Avslutt når du vil

    Prøv gratis + halv pris hele livet

    Lytt og les ubegrenset

    Kos deg med ubegrenset tilgang til mer enn 700 000 titler.

    • Lytt og les så mye du vil
    • Utforsk et stort bibliotek med fortellinger
    • Over 1500 serier på norsk
    • Ingen bindingstid, avslutt når du vil
    NO - Details page - Device banner - 894x1036