Kuuntele missä ja milloin haluat

Astu tarinoiden maailmaan

  • Pohjoismaiden suosituin ääni- ja e-kirjapalvelu
  • Uppoudu suureen valikoimaan äänikirjoja, e-kirjoja ja podcasteja
  • Storytel Original -sisältöjä yksinoikeudella
  • Ei sitoutumisaikaa
Lunasta tarjous
NO - Details page - Device banner - 894x1036
Cover for Case Studies for Optimal Control Schemes of Power System with FACTS Devices and Power Fault Analysis: & Some Stories of Academic Corruption on My Life

Case Studies for Optimal Control Schemes of Power System with FACTS Devices and Power Fault Analysis: & Some Stories of Academic Corruption on My Life

Kielet
Englanti
Formaatti
Kategoria

Tietokirjallisuus

This book is divided into three parts related to case Studies for optimal control schemes of power system with FACTS devices, and power system fault analysis, and some stories of academic corruption in my life.

• Part A: Optimal Control Schemes for Power System with FACTS Devices

• Part B. Calculation of Critical Distance in Faulted Meshed Power System

• Part C: Real Stories of Academic Corruption in My Life

I. Part A: Optimal Control Schemes for Power System with FACTS Devices:

Most of the control schemes introduced in the existing papers were designed either for eliminating current harmonics or eliminating voltage flickers or for load flow control. So, this work is devoted to find proper optimal control schemes for a system with series or shunt or series and shunt converters that can provide all functions together. Various optimal control schemes will be designed for systems with series, shunt and series-shunt converters with the objective to control the load flow through lines and to eliminate current harmonics and voltage flickers with different strategies for tracking.

II. Part B. Calculation of Critical Distance in Faulted Meshed Power System

Fault studies form an important part of power system analysis. The problem consists of determining bus voltages and line currents during various types of faults. If the fault location is known the problem can be easily solved. But if the fault location is unkown, it is difficult to solve the problem. If the fault location is known the problem can be easily solved. But if the fault location is unknown, it is difficult to solve the problem. This part provided a proper solution based on Gauess Seidal to find the critical distance in meshed power system

III. Part C: Real Stories of Academic Corruption in My Life

In this part, I will speak about the academic corruption I saw in some universities and academic institutions according to my experience with them.

© 2021 BookRix (E-kirja): 9783748771258

Julkaisupäivä

E-kirja: 12. tammikuuta 2021

Avainsanat

    Saattaisit pitää myös näistä

    Valitse tilausmalli

    • Yli miljoona tarinaa

    • Suosituksia juuri sinulle

    • Uusia Storytel Originals + eksklusiivisia sisältöjä kuukausittain

    • Turvallinen Kids Mode

    • Ei sitoutumisaikaa

    Standard

    Sinulle joka kuuntelet säännöllisesti.

    16.99 € /kuukausi
    • 1 käyttäjätili

    • 50 tuntia/kuukausi

    • Ei sitoutumisaikaa

    Lunasta tarjous
    Suosituin

    Premium

    Sinulle joka kuuntelet ja luet usein.

    19.99 € /kuukausi
    • 1 käyttäjätili

    • 100 tuntia/kuukausi

    • Ei sitoutumisaikaa

    Lunasta tarjous

    Flex

    Sinulle joka kuuntelet vähemmän.

    9.99 € /kuukausi
    • 1 käyttäjätili

    • 20 tuntia/kuukausi

    • Säästä käyttämättömät tunnit, max 20h

    • Ei sitoutumisaikaa

    Aloita ilmainen kokeilu

    Unlimited

    Sinulle joka haluat rajattomasti tarinoita.

    29.99 € /kuukausi
    • 1 käyttäjätili

    • Kuuntele ja lue rajattomasti

    • Ei sitoutumisaikaa

    Aloita ilmainen kokeilu

    Family

    Kun haluat jakaa tarinoita perheen kanssa.

    Alkaen 26.99 €/kuukausi
    • 2-6 tiliä

    • 100 tuntia/kk jokaiselle käyttäjälle

    • Ei sitoutumisaikaa

    2 käyttäjätiliä

    26.99 € /kuukausi
    Aloita ilmainen kokeilu