Introduction to Power System Protection

Bahasa
Inggris
Format
Kategori

Non Fiksi

Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers

The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0–5 ampere range for convenience of measurement.

The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When |I'| exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open.

System-protection components have the following design criteria: • Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. • Selectivity: Avoid unnecessary, false trips. • Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. • Economy: Provide maximum protection at minimum cost. • Simplicity: Minimize protection equipment and circuitry.

Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection.

The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.

© 2022 Dr. Hidaia Mahmood Alassouli (buku elektronik ): 9783985103119

Tanggal rilis

buku elektronik : 12 Mei 2022

Tag

    Yang lain juga menikmati...

    Selalu dengan Storytel

    • Lebih dari 900.000 judul

    • Mode Anak (lingkungan aman untuk anak)

    • Unduh buku untuk akses offline

    • Batalkan kapan saja

    Terpopuler

    Premium

    Bagi yang ingin mendengarkan dan membaca tanpa batas.

    Rp39000 /bulan
    7 hari gratis
    • 1 akun

    • Akses Tanpa Batas

    • Akses bulanan tanpa batas

    • Batalkan kapan saja

    • Judul dalam bahasa Inggris dan Indonesia

    Coba sekarang

    Premium 6 bulan

    Bagi yang ingin mendengarkan dan membaca tanpa batas

    Rp189000 /6 bulan
    7 hari gratis
    Hemat 19%
    • 1 akun

    • Akses Tanpa Batas

    • Akses bulanan tanpa batas

    • Batalkan kapan saja

    • Judul dalam bahasa Inggris dan Indonesia

    Coba sekarang

    Local

    Bagi yang hanya ingin mendengarkan dan membaca dalam bahasa lokal.

    Rp19900 /bulan
    7 hari gratis
    • 1 akun

    • Akses Tanpa Batas

    • Akses tidak terbatas

    • Batalkan kapan saja

    • Judul dalam bahasa Indonesia

    Coba sekarang

    Local 6 bulan

    Bagi yang hanya ingin mendengarkan dan membaca dalam bahasa lokal.

    Rp89000 /6 bulan
    7 hari gratis
    Hemat 25%
    • 1 akun

    • Akses Tanpa Batas

    • Akses tidak terbatas

    • Batalkan kapan saja

    • Judul dalam bahasa Indonesia

    Coba sekarang