Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers
The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0–5 ampere range for convenience of measurement.
The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When |I'| exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open.
System-protection components have the following design criteria: • Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. • Selectivity: Avoid unnecessary, false trips. • Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. • Economy: Provide maximum protection at minimum cost. • Simplicity: Minimize protection equipment and circuitry.
Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection.
The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.
© 2022 Dr. Hidaia Mahmood Alassouli (eBook): 9783985103119
Data wydania
eBook: 12 maja 2022
Tagi
Ponad 500 000 tytułów w cenie jednego abonamentu
Słuchaj i czytaj w trybie offline
Ekskluzywne produkcje audio Storytel Original
Tryb dziecięcy Kids Mode
Anuluj kiedy chcesz
Dla tych, którzy chcą słuchać i czytać bez limitów.
1 konto
Nielimitowany Dostęp
1 konto
Słuchanie bez limitów
Anuluj w dowolnym momencie
Dla tych, którzy chcą słuchać i czytać bez limitów.
1 konto
Nielimitowany Dostęp
1 konto
Słuchanie bez limitów
Anuluj w dowolnym momencie
Dla tych, którzy słuchają i czytają od czasu do czasu.
1 konto
10 godzin/miesięcznie
1 konto
10 godzin / miesiąc
Anuluj w dowolnym momencie
Dla tych, którzy chcą dzielić się historiami ze znajomymi i rodziną.
2-3 kont
Nielimitowany Dostęp
2–3 konta
Słuchanie bez limitów
Anuluj w dowolnym momencie
2 konta
59.90 zł /miesiącPolski
Polska