Dinle ya da oku

Sesli kitapların büyülü dünyasına adım at.

  • İlk 2 ay ₺124,99/ay
  • Binlerce sesli kitap ve e-kitap.
  • Dilediğin kadar dinle ya da oku.
  • Çevrimdışı modu.
  • İstediğin zaman iptal et.
Abonelik başlat
TR - Details page - Device banner - 894x1036
Cover for Case Studies for Optimal Control Schemes of Power System with FACTS Devices and Power Fault Analysis: & Some Stories of Academic Corruption on My Life

Case Studies for Optimal Control Schemes of Power System with FACTS Devices and Power Fault Analysis: & Some Stories of Academic Corruption on My Life

Dil
İngilizce
Format
Kategori

Kurgu Dışı

This book is divided into three parts related to case Studies for optimal control schemes of power system with FACTS devices, and power system fault analysis, and some stories of academic corruption in my life.

• Part A: Optimal Control Schemes for Power System with FACTS Devices

• Part B. Calculation of Critical Distance in Faulted Meshed Power System

• Part C: Real Stories of Academic Corruption in My Life

I. Part A: Optimal Control Schemes for Power System with FACTS Devices:

Most of the control schemes introduced in the existing papers were designed either for eliminating current harmonics or eliminating voltage flickers or for load flow control. So, this work is devoted to find proper optimal control schemes for a system with series or shunt or series and shunt converters that can provide all functions together. Various optimal control schemes will be designed for systems with series, shunt and series-shunt converters with the objective to control the load flow through lines and to eliminate current harmonics and voltage flickers with different strategies for tracking.

II. Part B. Calculation of Critical Distance in Faulted Meshed Power System

Fault studies form an important part of power system analysis. The problem consists of determining bus voltages and line currents during various types of faults. If the fault location is known the problem can be easily solved. But if the fault location is unkown, it is difficult to solve the problem. If the fault location is known the problem can be easily solved. But if the fault location is unknown, it is difficult to solve the problem. This part provided a proper solution based on Gauess Seidal to find the critical distance in meshed power system

III. Part C: Real Stories of Academic Corruption in My Life

In this part, I will speak about the academic corruption I saw in some universities and academic institutions according to my experience with them.

© 2021 BookRix (E-Kitap): 9783748771258

Yayın tarihi

E-Kitap: 12 Ocak 2021

Etiketler

Bunları da beğenebilirsin...

Storytel dünyasını keşfet:

  • Kids mode

  • Çevrimdışı modu

  • İstediğin zaman iptal et

  • Her yerde erişim

Sınırsız

Sınırsızca dinlemek ve okumak isteyenler için.

₺249.99 /ay
  • 1 hesap

  • Sınırsız erişim

  • İstediğin zaman iptal et

Abonelik başlat

Sınırsız Yıllık

Sınırsızca dinlemek ve okumak isteyenler için.

₺1499.99 /yıl
6 ay öde, 12 ay dinle
  • 1 hesap

  • Sınırsız erişim

  • İstediğin zaman iptal et

Abonelik başlat

Aile (2 hesap)

Hikayeleri sevdikleri ile paylaşmak isteyenler için.

₺379.99 /ay
  • 2 hesap

  • Sınırsız erişim

  • İstediğin zaman iptal et

Abonelik başlat

Aile (3 hesap)

Hikayeleri sevdikleri ile paylaşmak isteyenler için.

₺474.99 /ay
  • 3 hesap

  • Sınırsız erişim

  • İstediğin zaman iptal et

Abonelik başlat