Hlustaðu og lestu

Stígðu inn í heim af óteljandi sögum

  • Lestu og hlustaðu eins mikið og þú vilt
  • Þúsundir titla
  • Getur sagt upp hvenær sem er
  • Engin skuldbinding
is Device Banner Block 894x1036

Introduction to Power System Protection

Tungumál
enska
Format
Flokkur

Óskáldað efni

Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers

The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0–5 ampere range for convenience of measurement.

The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When |I'| exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open.

System-protection components have the following design criteria: • Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. • Selectivity: Avoid unnecessary, false trips. • Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. • Economy: Provide maximum protection at minimum cost. • Simplicity: Minimize protection equipment and circuitry.

Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection.

The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.

© 2022 Dr. Hidaia Mahmood Alassouli (Rafbók): 9783985103119

Útgáfudagur

Rafbók: 12 maj 2022

Aðrir höfðu einnig áhuga á...

Veldu áskrift

  • Yfir 900.000 hljóð- og rafbækur

  • Yfir 400 titlar frá Storytel Original

  • Barnvænt viðmót með Kids Mode

  • Vistaðu bækurnar fyrir ferðalögin

Vinsælast

Unlimited

Besti valkosturinn fyrir einn notanda

3290 kr /mánuði
3 dagar frítt
  • 1 aðgangur

  • Ótakmörkuð hlustun

  • Yfir 900.000 hljóð- og rafbækur

  • Engin skuldbinding

  • Getur sagt upp hvenær sem er

Prófaðu frítt

Family

Fyrir þau sem vilja deila sögum með fjölskyldu og vinum.

Frá 3990 kr/mánuði
3 dagar frítt
  • 2-6 aðgangar

  • 100 klst/mán fyrir hvern aðgang

  • Yfir 900.000 hljóð- og rafbækur

  • ‎Engin skuldbinding

  • Getur sagt upp hvenær sem er

2 aðgangar

3990 kr /á mánuði
Prófaðu frítt